Control Cable

JZ-YCY

Brand: RR Kable

Technical Specifications

Feature Specification
Nominal Voltage: Uo /U 300 / 500V
Insulation Resistance: Min. 20 GΩ x cm
Temperature Range: Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
Minimum Bending Radius: Flexing 10 x cable ø. Fixed installation 5 x cable ø
Test Voltage: 4000V
Breakdown Voltage: Min. 8000V

Application

For use as a data and control cable in machinery, computer systems etc. as well as a signal cable for electronics. The high level of screening ensures a high degree of interference protection. The screening density assures disturbance-free transmission of all signals and impulses.

Standard

Requirements adapted to DIN VDE 0245, 0281 Part 13.


Cable Construction

Bare copper, fine wire conductors, to EN 60228 Cl.5.
Core insulation of PVC TI2 EN 50363-3.
Black Core with continuous white numbering to DIN VDE 0293.
Green/Yellow earth core in outer layer (3 cores and above).
Cores stranded in layers with optimal lay-length.
Special PVC inner jacket.
Tinned copper, braided screen, approx 85% coverage.
Transparent special PVC outer sheath.

Properties

  •  The clear transparent PVC outer sheath accentuates the optical view of the tinned copper braid.
  •  PVC self-extinguishing and flame retardant according to EN 60332-1-2.
  •  JZ-YCY grey (RAL 7001) is available in oil resistant variant as JZ-YCY OR. The outer sheath provided here is of special PVC TM5 to BS EN 50363 -4.1.
  •  For oil resistant sheath kindly add ‘OR’ after the part nos.
  • EMC: Electromaganetic compatibillity to optimise the EMC features we recommend a large round contact of the copper braiding on both ends.

Related Product

RR Kable

JZ-500

  • Uo / U 300 / 500V
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kable

Control Cable (IS 694)

  • IS 694 marked, FIA/TAC
  • Electrolytic grade annealed copper Class-5 as per IS 8130, having uniform resistance properties
  • All black colour cores with continous white numbering, gn-yl core on outer most layer for earth if applicable
RR Kable

JZ-CY

  • Uo / U 300 / 500V
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kable

JZ-YCY

  • Uo /U 300 / 500V
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kable

JZ-YSY

  • Uo / U 300 / 500V
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kable

JB-YCY

  • Uo / U 300 / 500V up to 1.5 mm². Uo / U 450 / 750V for 2.5 mm² and above
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C