Control Cable

JB-YSY

Brand: RR Kable

Technical Specifications

Feature Specification
Nominal Voltage: Uo / U 300 / 500V up to 1.5 mm². Uo/U 450/750V for 2.5 mm² and above
Insulation Resistance: Min. 20 GΩ x cm
Temperature Range: Flexing -5°C to +70°C; Fixed installation -30°C to +70°C
Minimum Bending Radius: Flexing 20 x cable ø. Fixed installation 6 x cable ø
Test Voltage: 4000V
Breakdown Voltage: Min. 8000V

Application

These cables are used as measuring and control cables in food processing industries, packaging industries, tool machinery, plant installation and power stations. The steel braid ensures best possible protection against mechanical damage. The galvanized coating on the steel wire braiding not only helps protect against corrosion, but also notably improves the soldering properties.

Standard

Adapted to DIN/BS EN 50525-2-51


Cable Construction

Bare copper, fine wire conductors, to EN 60228 Cl. 5.
Core insulation of TI2, EN 50363-3.
Core identification : As per VDE 0293-302/HD 308 S2 (Refer appendix table No. 1-1)
Green/Yellow earth core in outer layer (3 cores and above).
Cores stranded in layers with optimal lay-length.
Special PVC inner jacket.
Galvanised steel wire screening.
Special PVC outer jacket.
Transparent Special PVC outer sheath (also available in grey)

Properties

 PVC self-extinguishing and flame retardant according to EN 60332-1-2.

Cable Design Parameters

Please complete the part numbers for these cables by adding the suffix (in place of ‘z’) for the sheath colour required, 3 – grey (RAL 7001), 6 – transparent.

Related Product

RR Kable

JZ-500

  • Uo / U 300 / 500V
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kable

Control Cable (IS 694)

  • IS 694 marked, FIA/TAC
  • Electrolytic grade annealed copper Class-5 as per IS 8130, having uniform resistance properties
  • All black colour cores with continous white numbering, gn-yl core on outer most layer for earth if applicable
RR Kable

JZ-CY

  • Uo / U 300 / 500V
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kable

JZ-YCY

  • Uo /U 300 / 500V
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kable

JZ-YSY

  • Uo / U 300 / 500V
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kable

JB-YCY

  • Uo / U 300 / 500V up to 1.5 mm². Uo / U 450 / 750V for 2.5 mm² and above
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C