Braided Cable

Li2Y(St)CY PiMF

Brand: RR Kable

Application

Absolute disturbance-free data transfer both for installed terminals in all areas of medicine and data technology. Also suitable for use in machine tool and steel producing industries, traffic signal systems, assembly lines and food processing.

Technical Data

  • Standard: Based on VDE 0812
  • Voltage Grade (Not for power installation): Max. 250 V
  • Test Voltage: Core / core 2000 V. Core / screen 1000V
  • Insulation Resistance: Min. 5000 GΩ x cm
  • Mutual Capacitance:

 0.22 mm² max., 70 nF/km

 0.34 mm² max., 70 nF/km

 0.5 mm² max., 75 nF/km

 1 mm² max., 85 nF/km

  • Inductance: Approx. 0.4 mH/km
  • Cross-Talk Attenuation: Min. 80 dB up to 1 MHZ
  • Characteristic Impedance at: approx. 85 Ω (>1 MHz)
  • Minimum Bending Radius : Fixed 10 x cable ø
  • Temperature Range: Flexing -5°C to +70°C. Fixed installation -30°C to +70°C

Cable Construction

Bare copper stranded 7 wire conductor.

Conductor make-up for

 0.22 mm² = 7 x 0.20 mm

 0.34 mm² = 7 x 0.25 mm

 0.5 mm² = 7 x 0.30 mm

 0.75 mm² = 7 x 0.37 mm

 1 mm² = 7 x 0.43 mm

Conductor Resistance (loop) at 20°C

 0.22 mm² = 186 Ω/km (max.)

 0.34 mm² = 115 Ω/km (max.)

 0.5 mm² = 78.5 Ω/km (max.)

 0.75 mm² = 58 Ω/km (max.)

 1 mm² = 39.2 Ω/km (max.)

  •  Core colours as per DIN 47100 (Refer table no. 2-1 of appendix)
  •  PiMF : (pair in metal foil) cores twisted in pairs, foil wrapped plastic coated aluminium foil and copper drain-wire tinned,
  •  100% coverage.
  •  PiMFs are stranded in layer.
  •  Core wrapping with plastic tapes.
  •  Overall copper screened braiding, 85 % coverage
  •  Special PVC outer sheath TM2, to EN 50363-4.1.
  •  Colour grey (RAL 7032).

Properties

PVC self-extinguishing and flame retardant according to EN 60332-1-2. The twisted-pair lay-up prevents electrical unbalances within the cable and this thus effectively suppresses cross-talking effects.