Flexible Multicore Cable

H03/H05V2V2H2-F & H03/H05V2V2-F

Brand: RR Kable

Technical Specifications

Feature Specification
Nominal Voltage 300 / 500V (H05V2V2H2-F / H05V2V2-F); 300 / 300V (H03V2V2H2-F / H03V2V2-F)
Insulation Resistance Min. 20 GΩ x cm
Temperature Range: Flexing -5°C to +90°C / Fixed Installation -30°C to +90°C / Fixed Installation 5 x cable ø
Minimum Bending Radius Flexing 7.5 x cable ø; Fixed installation 4 x cable ø
Test Voltage 4000V
Breakdown Voltage Min. 8000V

Application

For use in connections of household appliances and internal wiring purposes with high ambient temperatures and humid spaces

Standard

BS EN 50525-2-11.


Cable Construction

Bare copper, fine wire conductors, as per EN 60228 Cl.5.
PVC core insulation TI3, to EN 50363-3.
Harmonised core colour to HD 308 (Refer Appendix Table No. 1-1).
Cores stranded in layers with optimal lay-length.
PVC outer sheath TM3, to EN 50363-4.1

Properties

PVC self-extinguishing and flame retardant according to EN 60332-1-2.

Cable Design Parameters

Please complete the part numbers for these cables by adding the suffix (in place of ‘z’) for the sheath colour required, 1 – black (RAL 9005), 3 – grey (RAL 7001), 5 – white (RAL 9010).

Related Product

RR Kable

Ratnaflex Multicore Cable (IS 694)

  • IS 694 marked, FIA/TAC
  • Electrolytic grade annealed copper Class 5 as per IS 8130
  • Black, grey & white
RR Kable

Control Cable (IS 694)

  • IS 694 marked, FIA/TAC
  • Electrolytic grade annealed copper Class-5 as per IS 8130, having uniform resistance properties
  • All black colour cores with continous white numbering, gn-yl core on outer most layer for earth if applicable
RR Kable

JZ-BLACK 0.6/1 KV

  • Uo / U 0.6 / 1 kV
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kable

UL 2586

  • UL-758 UL 2586
  • 1000 Vac
  • -30ºC to + 150 ºC
RR Kable

UL 2587

  • Std. 758; Control cable of special – PVC to UL AWM; Style 2587 cores according to UL 1015
  • 600V
  • 3000V